Struggling with handrail compliance on disability ramps? Here are some tips to help.

Top mounted inline Handrails such as AR20 and AR40 used on disability ramps, require a substrate width of 1195+mm to meet the minimum 1000mm clear between requirements of AS 1428.

Space permitting, a substrate design width of 1245mm+ to achieve compliance & allow for stanchions to be placed 75mm in from edge of concrete is ideal. 

For ramps that return or double-back, the handrails on the landings require a minimum 1540mm clear between them. Top mounted Inline Handrails such as AR20 and AR40 used in this application will require a substrate width of 1665+mm to achieve the minimum 1540mm clear between, a requirement of AS 1428.

Space permitting, a landing substrate design width of 1690mm+ to achieve compliance & allow for stanchions to be placed 75mm in from edge of concrete is ideal.  

To save time, resource and ease of installation when specifying Moddex stair handrails or balustrades please consult Hot Design Tip or otherwise contact us on 1800 663 339 (Australia) or 0800 663 339 (New Zealand).